Rockwell Automation Publication 2094-RM001C-EN-P - May 2013

Chapter 12

Troubleshooting the Safe Speed Monitoring Drive

If outputs are already in a faulted state due to a previous fault, and a subsequent
Stop Category fault or Fault While Stopping fault occurs, outputs remain in a
faulted state, door control logic can be set to Unlock if feedback signals indicate
that Standstill Speed has been reached, and the drive continues to monitor for
faults.

If a Stop Category fault or Fault While Stopping fault occurs after Standstill
Speed has been reached and the drive has set door control logic to Unlock, the
drive goes to the Safe State.

Status Attributes

For diagnostic purposes, you can only view status attributes by accessing the
AxisServoDrive.GuardStatus tag in the Logix Designer application.

Guard Status Attributes

These attributes are stored in the AxisServoDrive.GuardStatus tag. Each bit
corresponds to a different attribute.

ATTENTION: If a fault occurs after Standstill Speed has been reached, door
control logic remains unlocked.

A Safe State fault can set the Door Control output (DC_Out) to OFF.

Table 36 - Guard Status Attributes

Bit

Display Text
Axis 1.

Description

0

GuardOKStatus

This bit indicates when there are no faults. It is set (1), when all of the Fault Status bits 1…31 are 0 (no faults). The bit is 0 if any Fault Status
bit from 1…31 indicates a fault (1).

1

GuardConfig
LockedStatus

This bit shows the status of the [Safety Lock Status] parameter. A 1 indicates the configuration is locked; a 0 indicates the configuration is
unlocked.

2

GuardGateDrive
OutputSatus

This bit shows the status of the drive’s Motion Power command to the drive. A 1 indicates Motion Power is enabled; a 0 indicates Motion
Power is disabled.

3

GuardStopInput
Status

This bit displays the logical value, 1 or 0, evaluated for the dual-channel SS_In input.

4

GuardStop
RequestStatus

This bit is set to 1 when a safe stop is initiated by either a transition of the SS_In input from ON to OFF or by a Stop Category fault.
This bit is reset to 0 when a successful SS Reset occurs and when the Operation mode is set to Disabled (0).

5

GuardStop
InProgressStatus

This bit is set to 1 when a safe stop is initiated by the transition of the SS_In input from ON to OFF with no active fault conditions. It is not set
to 1 when a Safe Stop is initiated by a Stop Category fault.
While set to 1, this bit is reset (0) if Standstill Speed is reached or any fault condition is detected.

6

GuardStop
DecelStatus

This bit is set to 1 if the configured Stop Delay [Maximum Stop Time] is active for a Safe Stop 1 or Safe Stop 2 while the drive is executing the
Safe Stop.
This bit is not set during a Category 0 Safe Torque Off Safe Stop.
This bit is reset (0) when Standstill Speed is detected, a Safe State fault occurs, or a SS Reset occurs.

7

GuardStop
StandstillStatus

This bit is set to 1 if a successful Safe Stop has been executed and the speed is less than or equal to the Standstill Speed.
This bit is set to 0 by an SS Reset or the occurrence of a Stop Category fault.
It is always 0 when the drive is configured for a Safe Torque Off without Standstill Speed Checking.