Chapter

8

Slave Modes for Multi-axis Cascaded Systems

This chapter describes the slave modes of safety operation and wiring examples of
cascaded multi-axis configurations.

Cascaded Configurations

Use the [System Configuration] parameter to define the drive’s position in the
system as Single Unit, Cascaded First Unit, Cascaded Middle Unit, or Cascaded
Last Unit. Only the middle or last drive in a multi-axis system can be configured
for slave modes.

For cascaded drives, connect the safety switches to the safety inputs (SS_In,
SLS_In, DM_In, ESM_In, and LM_In) of only the first (master) axis. Each
feedback for Safe Stop functions are connected to their respective axis. The
inputs are cascaded from one drive to the next by connecting the outputs from
the previous drive to the inputs of the next drive.

Topic

Page

Cascaded Configurations

89

Slave, Safe Stop Mode

91

Slave, Safe Stop Parameter List

91

Slave, Safe Stop Wiring Examples

93

Slave, Safe Limited Speed Mode

96

Slave, Safe Limited Speed Parameters

96

Slave, Safe Limited Speed Wiring Examples

97

Slave, Safe Limited Speed Status Only Mode

99

Slave, Safe Limited Speed Status Only Parameter List

99

Slave, Safe Limited Speed Status Only Wiring Examples

100

Multi-axis Connections

101