Slave Modes for Multi-axis Cascaded Systems

Chapter 8

Slave, Safe Limited Speed
Status Only Mode

When properly configured for Slave, Safe Limited Speed Status Only mode, the
Safe Speed Monitor Option module performs the same functions as Safe Limited
Speed Status Only mode as described on

page 84

. However, the drive regards the

Door Monitor input as a Door Control output from an upstream axis, and
performs a logical AND with its internal Door Control signal to form the
cascaded Door Control output.

The SLS_Out output of the last drive in a cascaded chain goes high only when all
axes are below the Safe Speed Limit. In Safe Limited Speed Status Only mode,
each subsequent unit does not enable Safe Limited Speed until the previous unit
has reached the Safe Speed Limit.

Door Monitoring and Enabling Switch Monitoring functions are not allowed in
this mode.

Slave, Safe Limited Speed
Status Only Parameter List

To configure the drive for Slave, Safe Limited Speed Status Only monitoring, set
these parameters in addition to the Slave, Safe Stop parameters listed on

page 91

and the Slave, Safe Limited Speed parameters listed on

page 96

. See

Multi-axis

Connections

on

page 101

for details on configuring slave drives.

Table 28 - Slave, Safe Limited Speed Status Only Parameters

TIP

Only the middle and last drive in a multi-axis system can be configured for
slave modes.

Tab

Parameter Name

Description

Values
(Safety Configuration Tool)

Safety
Change System
Configuration

System Configuration

Defines whether the drive is a single unit or if it occupies
a first, middle, or last position in a multi-axis cascaded
system.

Options:

Cascaded Middle Unit
Cascaded Last Unit

Operation Mode

Defines the primary operating mode of the speed
monitoring safety functions.

Option:

SafeStop-Safe Limited Speed Status Only

Safe Limited Speed
Change Safe Limited
Speed Configuration

Safe Limited Speed
Hysteresis

Provides hysteresis for SLS_Out output when Safe
Limited Speed monitoring is active.

Default:

0

Range:

10…100% when [Operation Mode] =
SafeStop-SafeLimitedSpeedStatusOnly