Rockwell Automation Publication 2094-RM001C-EN-P - May 2013

131

Safety Configuration Example

Chapter 11

Configure Safe Max Speed Tab Parameters

Refer to

Appendix B

beginning on

page 145

for default, minimum, and

maximum values for these safety parameters.

Follow these steps to configure the Safe Max Speed tab parameters.

1. Expand the Safety folder to gain access to the Safe Max Speed tab.

2. Under Safety Configuration, choose Safe Max Speed.

The Safe Max Speed tab dialog box opens.

3. Check Enable Maximum Speed Monitoring.

4. Enter the desired [Safe Maximum Speed Limit] parameter value.

5. Click Apply.

If all your parameter settings are valid, the
configuration is applied.

If one or more of your parameter settings are
invalid, the command fails.

TIP

If a rotary feedback device is used, the units are revolutions per minute
(RPM). If a linear feedback device is used, the units are in millimeters per
second (mm/s).