Speed resolution accuracy for linear systems – Rockwell Automation 2094-EN02D-M01-S1 Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety Reference Manual User Manual

Page 45

Advertising
background image

Rockwell Automation Publication 2094-RM001C-EN-P - May 2013

45

General Device and Feedback Monitoring Configuration

Chapter 5

Table 10 - Encoder Resolution 5000 lines/rev

Speed Resolution Accuracy for Linear Systems

Table 11 - Encoder Resolution 500 lines/mm

Table 12 - Encoder Resolution 1000 lines/mm

Overspeed Response Time
Setting

Speed (RPM)

1

10

100

1000

2400

42

0.503

0.533

0.833

3.833

8.500

48

0.252

0.267

0.417

1.917

4.250

60

0.126

0.133

0.208

0.958

2.125

84

0.063

0.067

0.104

0.479

1.063

132

0.031

0.033

0.052

0.240

0.531

228

0.016

0.017

0.026

0.120

0.266

420

0.008

0.008

0.013

0.060

0.133

Overspeed Response Time
Setting

Speed (mm/s)

0.01

0.1

1

10

100

400

42

0.083

0.084

0.087

0.117

0.417

1.417

48

0.042

0.042

0.043

0.058

0.208

0.708

60

0.021

0.021

0.022

0.029

0.104

0.354

84

0.010

0.010

0.011

0.015

0.052

0.177

132

0.005

0.005

0.005

0.007

0.026

0.089

228

0.003

0.003

0.003

0.004

0.013

0.044

420

0.001

0.001

0.001

0.002

0.007

0.022

Overspeed Response Time
Setting

Speed (mm/s)

0.01

0.1

1

10

100

200

42

0.042

0.042

0.045

0.075

0.375

0.708

48

0.021

0.021

0.023

0.038

0.188

0.354

60

0.010

0.011

0.011

0.019

0.094

0.177

84

0.005

0.005

0.006

0.009

0.047

0.089

132

0.003

0.003

0.003

0.005

0.023

0.044

228

0.001

0.001

0.001

0.002

0.012

0.022

420

0.001

0.001

0.001

0.001

0.006

0.011

Advertising