Chapter 3. Concepts

Data Flow

Arrows connecting nodes for a reconvergent path diagram will point in
the direction of the asynchronous data flow, which (due to the underlying
async ’ack’ backward-propagation) is sometimes in the opposite direction
of the User Logic. These backward-propagation signals will be shown
with dotted line arrows. These backward-propagation signals are
normally hidden/abstracted out, but they are necessarily visible during
Critical Path Timing Analysis, particularly when dealing with
reconvergent paths. See

Analyzing Critical Paths

for more information.

Selection

The

Selection Options control the selection of objects in the Critical Path Diagram view.

Selection Options

Option

Default

Description

Select

Enabled

This radio button controls the action applied to objects in the
selection region. This setting causes the objects to be added to
the current ACE selection set.

Deselect

Disabled

This radio button controls the action applied to objects in the
selection region. This setting causes the objects to be removed
from the current ACE selection set.

Label

The

Label options control the text labels on graph nodes and arrows (instances and net

abstractions) in the Critical Path Diagram view. Note that these labels are only displayed when there is
enough room for them to be printed on-screen. It may be necessary to Zoom In to provide sufficient area
for all the desired text to be displayed.

Label Options

Option

Description

Pipeline Stages

Displays the number of pico-pipeline stages it takes to traverse the node or arrow.

1)

Delays

Displays the delay (in ps) to traverse each node or arrow.

Fanouts

Displays the fanout of the net represented by the arrow.

2)

Instance Names

Displays the instance name each graph node represents.

Instance Types

Displays the instance type (cell) for each graph node.

Net Names

Displays the net name represented by each arrow.

2)

Note:

1)

Only relevant for asynchronous devices. Synchronous target devices will never report stages.

2)

Only displayed when the ”Layer” option Intermediate Nodes is enabled, so that arrows indicate

individual nets.

Tool Tip Text

The

Tooltip options control the tooltip content while hovering over graph nodes and

arrows in the Critical Path Diagram view.

Tooltip Options

Option

Description

None

No tooltips will be displayed for nodes or arrows.

Pipeline Stages

Displays the number of pico-pipeline stages it takes to traverse the node or arrow.

3)

UG001 Rev. 5.0 - 5th December 2012

http://www.achronix.com

150