Analyzing Critical Paths
Chapter 4. Tasks
Figure 4.15: Critical Path Diagram with net ”s[30]” selected. Note that the single net is represented by two
arrows.
Viewing Critical Paths in the Schematic Viewer
Currently, ACE does not have its own built-in schematic viewer. Viewing critical paths must be done in the
synthesis tool. In order to facilitate this, ACE can optionally generate a Tcl script with find commands for
objects along each critical path.
To view critical paths in the synthesis tool:
1. In the
, click on the Save Script File toolbar button (
) to open the
2. Enter a valid file in the
and click Save.
3. Source the saved script file from within the synthesis tool’s Tcl prompt.
4. After the file is sourced, open the synthesis tool’s schematic viewer. At the Tcl prompt, type
”
select one path
<
path id >”
to view a given path, where the <path id > is the value from the Path column of the table in the
Critical Paths view, and/or the Path Id value from one of the
281