Achronix ACE Version 5.0 User Manual

Page 23

Advertising
background image

Editors

Chapter 3. Concepts

Achieved NF

This calculated value shows the exact ”Feedback Divider
’NF’” value which will be used by the PLL. This may
differ slightly from the requested value; the closest
approximate value will be chosen if an exact match is not
possible.

Clkout Driving
External Feedback
Path

Y

Selects which of the currently-enabled clock outputs will
drive the external feedback path. Note that Phase
Adjustment is not allowed in the Feedback Path.

Enable sbus ports

Y

When selected, the sbus ports will be exposed in the
generated HDL file(s).

Feedback Modes

There are three feedback modes available to the PLL. Some allow fractional feedback,

others allow deskew.

PLL Feedback Modes

Mode

Fractional Feedback?

Deskew?

Algorithm

Pure Internal

Y

N

F

V CO

=(NF/NR)*F

ref

Pure External

N

Y

F

V CO

=(ODn*OSn/NR)*F

ref

Mixed

N

Y

F

V CO

=(NF*ODn*OSn/NR)*F

ref

Pure Internal Feedback

When internal feedback mode is selected, the VCO clock is divided by the ”Feedback Divider ’NF’” only.
In this mode, the PLL can have both integer and fractional feedback divider values. The ”Clkout Driving
External Feedback Path” option becomes disabled in this mode, since it is irrelevant. Deskewing is not
possible in this mode.

Pure External Feedback

When external feedback mode is selected, the VCO clock is divided by the Output Divider (ODn) and
(optionally) the Output Synthesizer (OSn). The ”Clkout Driving External Feedback Path” option becomes
enabled in this mode, and the ”Feedback Divider ’NF’” option becomes disabled. In this mode, it is not
allowed to feedback a clock output that has Phase Adjustment enabled.

4

Mixed Feedback

Mixed feedback mode is a modified version of Pure External feedback mode, in that the Feedback Divider
integer value is also in the deskew feedback path. As with Pure External mode, Phase Adjustment is not
allowed in the feedback path. The ”Clkout Driving External Feedback Path” option becomes enabled in this
mode, as does ”Feedback Divider ’NF’”.

4

Phase rotation in the feedback path will cause the PLL to unlock. If Phase Adjustment is required on any output clocks, it must be

used on outputs which are not in the feedback path.

11

http://www.achronix.com

UG001 Rev. 5.0 - 5th December 2012

Advertising