Copying implementations, Setting the active implementation, Removing implementations – Achronix ACE Version 5.0 User Manual

Page 257: Configuring implementation options, Opening output files in an editor, 12 copying implementations, 13 setting the active implementation, 14 removing implementations, 15 configuring implementation options, 16 opening output files in an editor

Advertising
background image

Working with Projects and Implementations

Chapter 4. Tasks

Copying Implementations

To create a new

implementation

that is a copy of an existing implementation,

1. In the

Projects View

, select (

activate

) the implementation to be copied

2. Select the Create Implementation (

) toolbar button in the Projects View

3. In the pop-up

Create Implementation dialog

,

(a) type in the name of the new implementation

(b) check the Copy Option Values from Active Implementation checkbox

(c) select the Finish button

After clicking Finish, the new implementation now appears under the selected project in the Projects view.
The new implementation is set to be the

active implementation

and contains

implementation options

values

copied from the source implementation. A new implementation directory structure is also created under
the project directory if it does not already exist.

Setting the Active Implementation

To change the

active implementation

in the GUI, do one of the following:

• Single-click on an implementation in the Projects view, activating the selected implementation.

• Single-click on a project in the Projects view, activating the selected project’s first implementation.

Changing the active implementation causes the flow status to be cleared and changes the target for all flow
operations to the new active implementation.

Removing Implementations

To remove an implementation from a project in the workspace:

1. Select an implementation in the Projects view.

2. Click on the Delete toolbar button (

) in the Projects view.

After clicking Delete, the implementation no longer appears in the Projects view.

Removing an

implementation from a project causes all settings for the implementation to be deleted from the project
file once the project is saved.

Configuring Implementation Options

To configure

implementation

options in the workspace:

1. Select an implementation in the

Projects view

, changing the active implementation to the selection.

2. In the

Options view

, use the controls to configure the available implementation options for the active

implementation.

After changing implementation options in the

Options view

, the

flow status

is cleared. A change to an

implementation option requires the

flow

to be re-run for that implementation in order for the changes to

affect the results of the flow. The changes to the implementation options are not saved until the affected
project is saved.

Opening Output Files in an Editor

To open an output file in the editor area, double-click on the output file in the Projects view. The output file
now appears in a text editor in the editor area.

Note:

Editing an output file is not recommended.