144 poe usage-threshold – Interlogix NS3702-24P-4S Command Line Guide User Manual

Page 244

Advertising
background image

-244-

poe temperature-threshold <0-100>

poe

Power Over Ethernet

temperature-threshold

Set a lower high temperature threshold for the secondary temperature alarm in degrees C.

<0-100>

Specifies the new threshold temperature.

Default:

80

Usage Guide:

To enable PoE Temperature Protection.

Example:

To enable PoE Temperature Protection (70 degrees C).

Switch# configure terminal
Switch (config)# poe temperature-threshold 70

4.2.144 poe usage-threshold

Command:

poe usage-threshold <1-99>

poe

Power Over Ethernet

usage-threshold

The poe usage-threshold command sets a percentage threshold above which the system sends a

log or SNMP trap.<1-99>: The -threshold percentage configured with this command.

<1-99>

The usage-threshold percentage configured with this command.

Default:

85

Usage Guide:

To configure PoE Usage Threshold.

Example:

To configure PoE Usage Threshold (90 %).

Switch# configure terminal
Switch (config)# poe usage-threshold 90