Interlogix NS3702-24P-4S Command Line Guide User Manual
Page 332
![background image](/manuals/679209/332/background.png)
-332-
Switch # show interface GigabitEthernet 1/1 switchport
Name: GigabitEthernet 1/1
Administrative mode: access
Access Mode VLAN: 1
Trunk Native Mode VLAN: 1
Administrative Native VLAN tagging: disabled
Allowed VLANs: 1-4095
Hybrid port configuration
-------------------------
Port Type: C-Port
Acceptable Frame Type: All
Ingress filter: Disabled
Egress tagging: All except-native
Hybrid Native Mode VLAN: 1
Hybrid VLANs Enabled: 1-4095
4.20.20 show interface <port_type> <port_type_list> veriphy
Command:
show interface <port_type> <port_type_list> veriphy
show
Show running system information
interface
Interface status and configuration
veriphy
Run cable diagnostics and show result.
Default:
N/A
Usage Guide:
To display the result of Cable Diagnostics.
Example:
To display the result of Cable Diagnostics for interface GigabitEthernet 1/1.
Switch # show interface GigabitEthernet 1/1 veriphy
Starting VeriPHY - Please wait
Interface Pair
A Length P air B, Length
---------------------- ------ ------ ------- -------
GigabitEthernet 1/1 OK 3 OK 3