42 green-ethernet led on-event, 43 gvrp, 44 gvrp max-vlans – Interlogix NS3702-24P-4S Command Line Guide User Manual

Page 69

Advertising
background image

-69-

4.2.42 green-ethernet led on-event

Command:

green-ethernet led on-event error | link-change <0-65535>

error Set LEDs intensity to 100% if an error occurs.

link-change Specifies how long to turn LEDs intensity into 100%, when a link changes state.

<0-65535> Number of seconds to set LEDs intensity at 100% at link change.

Default:

N/A

Usage Guide:

To configure LED Power on-event to trigger LED light

Example:

To configure LED Power on-event as tabled below:

Switch# configure terminal
Switch (config)# green-ethernet led on-event error link-change 55

4.2.43 gvrp

Command:

gvrp

Default:

Disable

Usage Guide:

To enable GVRP.

Example:

To enable GVRP.

Switch# configure terminal
Switch (config)# gvrp

4.2.44 gvrp max-vlans