3-18

Chapter 3: INSTALLATION & WIRING

N-8050DS/8540DS

YS-13A Wall-mount box

Oval head combination screw M4 x 25
(supplied with the N-8050DS/8540DS)

Wall
surface

N-8050DS only

Acoustic material (

supplied with the N-8050DS

)

Note
Lay it down along the inside of the box.

The N-8050DS/8540DS comes with 2 types of screws: oval head
combination screw M4 x 25 and oval head slotted screw UNC No.6
x 18.
For the electrical box provided with unified threads, use the oval
head slotted screws UNC No.6 x 18.

Accessory screws

3.5.2. N-8050DS/8540DS

Attach the N-8050DS/8540DS to the YS-13A Wall-mount box installed on a wall.

Notes
• When controlling an electronic lock with the N-8050DS/8540DS unit, use

"Torx" screws to attach the unit at installation so that it cannot be detached
easily.

• When installing the N-8050DS/8540DS at outdoor or locations where it gets

wet with water, tightly seal the panel edges. Besides, provide a weep hole at
the underside of the mounting box to permit water to drain off.

• When installing the N-8050DS/8540DS under difficult environmental

conditions such as in coastal areas or at humid locations, cover the inside of
the N-8050DS/8540DS with coating. For the coating method, consult your
TOA dealer.

Seal the panel edges.

N-8500DS/8540DS's front panel

162

92

35

83.5

115

[Installation completion drawing]

Unit: mm