Chapter 3: INSTALLATION & WIRING

[Connecting to the PBX's analog E&M interface]

Connect the PBX's transmitting line to the unit's RX terminal, and the PBX's receiving line to the TX terminal.
Also connect the PBX's M (Mouth) line to the unit's E (Ear) terminal, and the PBX's E line to the M terminal.

CH1

TX

RX

C

M

TX

RX

C

E

M

E

CH2

N-8000MI's PBX interface terminal

To PBX analog E&M interface's transmitting line (T2)

To PBX's ground point

To PBX analog E&M interface's M and E lines

To PBX analog E&M interface's receiving line (R2)

2 channels

To PBX analog E&M interface's transmitting line (T1)

To PBX's ground point

To PBX analog E&M interface's M and E lines

To PBX analog E&M interface's receiving line (R1)

[Connecting to the Intercom's Tie-Line Unit]

Connect the intercom's transmitting line to the unit's RX terminal, and the receiving line to the TX terminal.

CH1

M

TX

RX

C

E

M

TX

RX

C

E

CH2

N-8000MI's PBX interface terminal

To Intercom's transmitting
line (T1)

To Intercom's receiving
line (R1)

To Intercom's transmitting
line (T2)

To Intercom's receiving
line (R2)

2 channels

Notes
• The "C" terminals for CH1 and CH2 are internally connected to the unit body (functional earth terminal).
Do not ground the Functional earth terminal (No. 6 on

p. 1-12

) in this PBX connection.

Tips
• Output level and input sensitivity can be adjusted in the range of 0 to 15 dB depending on the equipment to

be connected and cable length. (Refer to

p. 5-40

.)

• The Line attribute (Address signaling) and Line start method (Start dial supervision signaling) can be set for

the connected equipment. (Refer to

p. 5-40

.)

Tip
Output level and input sensitivity can be adjusted
in the range of 0 to 15 dB depending on the
equipment to be connected and cable length.
(Refer to

p. 5-40

.)

Advertising