Chapter 5: SYSTEM SETTINGS BY SOFTWARE

4.4. Using Unit Scan

Scan Exchanges, Multi interface units and IP stations connected to the local area network.
Note
The equipment scan function can only be used within the effective broadcast range.

Step 1. Confirm that the system is connected to the network and that power is being supplied to the system.

The LNK/ACT indicator on the exchange and multi interface unit, and FD indicator on the IP station
will light.

Step 2. Press "Unit Scan" button or select "Scan

Unit scan" from the menu bar. This will cause the MAC

address, Model number, IP address, Subnet mask, Default gateway, Web port, and Name of the
exchange connected to the local area network to be displayed.

Note
The followings are factory-preset values.

IP address:

192.168.1.1

Subnet mask:

255.255.255.0

Default gateway: 0.0.0.0
Web port:

80

Name:

N-8000EX, N-8010EX, N-8000MI, N-8500MS, or N-8540DS