Toa N-8000 Series Ver.1.41 User Manual

Page 201

Advertising
background image

5-57

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Station: Function Settings

Step 2. Set individual items.

(1) Incoming call mode

Call receiving mode can be selected either "Automatic Connection" or "Continuous Call". Call with a call
tone or without a call tone can be set on both modes.
The door station is fixed to "Automatic connection" mode.

(2) Level

Microphone sensitivity: Station hands-free microphone sensitivity can be adjusted in three increments

from 1 (minimum) to 3 (maximum). The default sensitivity is Level 2.

Note
The sensitivity for the handset microphone is fixed (not adjustable).

Speaker output:

Station speaker output level can be adjusted in five increments from 1 (minimum)
to 5 (maximum). The default sensitivity is Level 3.

Call volume:

Station call volume can be adjusted in five increments from 1 (minimum) to 5
(maximum). The default sensitivity is Level 3.

(3) Group call (max. 15) (Master station only)

Set a group of up to fifteen stations that will be called simultaneously when the station being set now is
called. With this setting, even when a called station is busy, any registered station in the group can
respond.

(4) Calls transferred to (Master station only)

Set the station number to which each transfer is to be directed.
Call forwarding receiving station can be set only when the call forwarding function of the Exchange is
enabled. (Refer to

p. 5-30

)

Note
The station to be called via Multi interface unit cannot be programmed as a transfer destination station.

(5) BGM

Set whether the station receives BGM broadcasts. If receiving, place a checkmark and select the BGM
channel number (1 – 8; Channel).

(6) Door station mode (Door station only)

Set whether to operate the door station in door station mode*.
* The call tone sounds only once at the door station when the door station calls the pre-programmed

master station. The call timeout and conversation timeout are set to 30 seconds each.

(7) Access to priority call operation (Master station only)

Enables the station to initiate priority calls.

(8) Refusal of priority call operation

Enables the station connected to the N-8000EX to refuse priority calls from other stations.
For the station connected to the N-8010EX, this function is fixed to ON (with the checkbox ticked).

(9) Access to paging call operation (Master station only)

Enables or disables paging calls from the station.

(10) External equipment control (Master station only)

Set whether the one-shot make output or make/break output is operated at the station.

(11) Door Remote

Set the Multi interface unit's unit number and contact output terminal number to be used for door remote
control.