Chapter 3: INSTALLATION & WIRING

4. WIRING

4.1. Exchange Connection

N-8000EX/8010EX Exchange

To AC mains or a UPS
(Uninterruptible power supply system)*.

16 lines

Note

Be sure to ground.

Both upper and lower terminals (clip terminals)
are internally connected.

Mini-clamp connector
232D-02S1B-DA5 (DDK)
(Supplied with the N-8000EX/8010EX)

Lines should be twisted

E-7000TB
Terminal board

Station

If there is a danger of lightning strikes,
insert an appropriate power gap arrester
into the power line.

* Select an appropriate UPS taking into consideration the total power consumption of all system components

and the required backup time, and also the requirement that the UPS should employ the on-line power
system.

Reference
Exchange: 50 W (rated)
8-Port 10M/100M Switching Hub: 10W (Differs depending on products.)

Note
Once the station line connected between a station and
the exchange is short-circuited or a ground fault occurs
on the cable, power cannot be supplied to the station
even when the short or ground fault is removed.
To restore the situation, be sure to disconnect the cable
connector at the station or exchange, and then connect it
again after several seconds.