N-8000mi multi interface unit, Front, Rear – Toa N-8000 Series Ver.1.41 User Manual

Page 25

Advertising
background image

1-12

Chapter 1: GENERAL DESCRIPTION

6.3. N-8000MI Multi Interface Unit

[Front]

1 2 3 4 5

[Rear]

1. Reset key [RESET]

Pressing this key reactivates the exchange.

2. LNK/ACT indicator [LNK/ACT] (Green)

Lights when connected to a network, and flashes
while transmitting or receiving data.

3. Status indicator [STATUS] (Red)

Continuously lights while data is written to an
internal storage medium (FlashMemory).
Flashes if there is a failure. (Refer to

p. 8-8

.)

4. Power indicator [POWER] (Green)

Lights when power is supplied to the unit.

5. MAC address

This is the address*

1

used by the unit. Since the

relationship of each exchange location to its MAC
address is established when setting the network
attributes, keep track of this relationship for later
use.

*

1

The inherent address assigned to each network
component, expressed in 12-digit hexadecimal
notation.

M

E

M

E

6

7

8

9

10

11

12

13

14

15

6. Functional earth terminal [SIGNAL GND]

Be sure to ground this terminal unless the unit
connects to a PBX.
Note: This terminal is not for protective earth.

7. AC inlet

Connects the supplied power cord.
Note
If there is a danger of lightning strikes, insert an
appropriate surge arrester into the power line.

8. Cord clamp

Pass the power cord through this clamp to
ensure that the plug does not pull out when the
unit is mounted to a wall. (Refer to

p. 3-7

.)

9. Contact input terminals [CONTACT IN]

No-voltage make contact inputs.
Short-circuit current: 10 mA, Open-circuit
voltage: 12 V

10. Contact output terminals [CONTACT OUT]

Relay contact outputs.
Withstand voltage: 24 V DC, Control current:
Maximum 0.5 A

11. Input volume controls

[EXTERNAL SIGNAL 1, 2]
Use these controls to adjust the audio input
levels for channels 1 and 2 according to the input
sources.

12. Audio input terminal [AUDIO IN]

Includes audio inputs (maximum 0 dB*

2

, over 10

kΩ, balanced) and contact inputs (no-voltage
make contact, short-circuit current: 10 mA, open-
circuit voltage: 12 V).

13. Audio output terminal [AUDIO OUT]

Includes audio outputs (maximum 0 dB*

2

, under

600 Ω, balanced) and control outputs (relay
contact withstand voltage: 24 V DC, control
current: maximum 0.5 A).

14. PBX interface terminal [PBX IF]

Connects to the Exchange of the EXES-2000 or
EXES-6000 system by a tie-line, or the PBX
exchange via the analog E&M interface.

15. Network connection terminal [10/100M]

Connects to a 10BASE-T- or 100BASE-TX-
compatible network. (Ethernet RJ-45 jack)

*

2

0 dB = 1 V

Advertising