Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Multi Interface: Contact Output

5.5.6. Contact output setting

Step 1. Click on the Contact Output tab. The setting screen is displayed.

Step 2. Set each item of "Contact output."

Set the access number for the contact output terminal to be activated when the station performs
external equipment control (one-shot make output or make/break output).

(1) Access No. digit

Enter 2 – 4 digit numbers to be used when controlling external equipment at the station.

(2) Contact output No. (Can't be edited.)

The Multi interface unit's contact output terminal number.

(3) Access No.

Set the access number of the digit set in "Access No. digit", which is used to control external equipement
at the station.

(4) Line status

Select the line to be diagnosed.
The specified contact output terminal is closed when such status is judged abnormal that the CPU failure
is detected on the line or the line is not connected though the station number has been registered.

(5) Network status

Select the equipment to be diagnosed.
The specified contact output terminal is closed when the equipment is judged failed if no response is
detected from it.