5-58

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Station: Function Settings

(12) Calling station indication/CCTV control

Control output No.: Set the Multi interface unit's unit number and contact output terminal number, which

provide a make signal when the station is called.

Called station's No.: Provides a make contact when the station to be set here is called. Up to 8 stations

can be set.

(Example)
The operation example illustrated below is based on the following settings:

Station No.: 101
Control Output

MI Equipment No.: 5
Contact output No.: 3

Called station's No.: 105

Call

No.101

No.105

1

0

5

N-8000MI (Equipment No. 5)

Contact Output No. 3

Make contact

The Multi interface unit's (equipment No. 5) Contact No. 3 closes when the station No. 101 calls the
station No. 105.