Page 202
5-58
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Station: Function Settings
(12) Calling station indication/CCTV control
Control output No.: Set the Multi interface unit's unit number and contact output terminal number, which
provide a make signal when the station is called.
Called station's No.: Provides a make contact when the station to be set here is called. Up to 8 stations
can be set.
(Example)
The operation example illustrated below is based on the following settings:
Station No.: 101
Control Output
MI Equipment No.: 5
Contact output No.: 3
Called station's No.: 105
Call
No.101
No.105
1
0
5
N-8000MI (Equipment No. 5)
Contact Output No. 3
Make contact
The Multi interface unit's (equipment No. 5) Contact No. 3 closes when the station No. 101 calls the