Paging zone settings, P. 5-61, P.5-61 – Toa N-8000 Series Ver.1.41 User Manual

Page 205

Advertising
background image

5-61

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Chapter 5: SYSTEM SETTINGS BY SOFTWARE

Paging Zone Settings

5.8. Paging Zone Settings

Step 1. Click "Paging" to display the following setting screen.

Step 2. Enter the paging number digit.

Enter the number 1, 2 or 3 in the input box for [Paging No. digit].
Zones are automatically indicated depending on which number is set. (For example, entering "1"
displays zones 1 through 9 for editing, entering "2" displays zones 01 though 99 for editing, etc.) The
maximum number of zones is 160.

Step 3. Enter the paging port number to be used.

Enter the start paging port number to be used in the system. The valid range is from 1 to 65535. The
N-8000 system uses (the number of Exchanges) x 4, (the number of Multi interface units) x 4 and (the
number of IP Stations) x 4 consecutive ports starting with the start port.

Note
Take care not to duplicate the number with the UDP port number set on

p. 5-25

,

5-33

,

5-45

, and

15000 that is internally used.

Step 4. Enter a zone name.

Double-clicking the cell (paging 1 – ) located under the zone number allows the zone name to be
edited. The zone name can be up to eight characters long.

Step 5. Select stations and external PA paging outputs included in each zone.

Click the desired cell to checkmark it.