4-50

W A N s u i t e 5 2 6 0 / 5 2 3 0

Figure 4.42

Network Interface Test Details Screen

BERT Table on the Network Interface Test Details Screen

The BERT table lets you set the test parameters listed below.

Setting

Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.

Values: Net, Use Service, Idle, Channel 1...31
Default: Net

BERT Pattern

Specifies the pattern to be transmitted during a test for the selected port.

Values: Marks, QRSS, 511, 2047, 2

15

, Spaces

Default: QRSS

NOTICE:

The 2

15

pattern is the ITU (European) version, not the ANSI version.

Test Duration

Specifies the length of time for which the test should run for the selected port.

Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes

Service Index

Selects the channels with a service to BERT (refer to the "Service Table
Screen"
on page 4-19)
.

Rate

Sets the bit rate to BERT for each selected channel. If “Nx64K” is selected,
the ones density requirements of the E1 network line must be ensured. If
“Nx56K” is selected, ones density for the selected DS0 channel is maintained.

Values: Nx56K, Nx64K

Default:Nx64K

Pattern Sync

Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,