Error status and alarm thresholds table, Error status and alarm thresholds table -6 – Verilink WANsuite 5230 (34-00304.F) Product Manual User Manual

Page 36

Advertising
background image

3-6

W A N s u i t e 5 2 6 0 / 5 2 3 0

Framing

Selects the framing for the network side of the DSU/CSU.

Values

CCS, CAS, Unframed

Default: CCS

Coding

Sets the network side line coding.

Values: HDB3, AMI
Default: HDB3

Timing

Sets the timing source to synchronize the unit’s internal timing generators. In
all cases, slips are controlled to occur on frame boundaries at the Network
ports when timing synchronization is lost. The options are as follows:

Network 1 (5260)

“Function” parameter (on the Network 2 screen) in “Slaved” mode

Internal,

Network 1, Network 2, Serial 1, Serial 2

“Function” parameter (on the Network 2 screen) in Network mode

Internal,

Network 1, Serial 1

Network 2 (5260)

“Function” parameter in “Slaved” mode

timing parameter is ignored in

Slave mode

“Function” parameter in Network mode

Internal, Network 2, Serial 2

Network (5230)

Internal, Network, Serial

Definitions of the timing sources are as follows:

Internal – The unit’s internal frequency standard (E1 2.048 Mbps ± 50 bps)
is used for all timing.

Network 1, Network 2, Network – Timing is derived from the Network port
recovered clock.

Serial 1, Serial 2, Serial – Timing is derived from the Serial port recovered
clock.

CRC4 Mode

Provides line integrity detection to determine if bit errors are present on the
line.

Values: Disable, Enable
Default: Disable

Error Status and Alarm Thresholds Table

The unit can be programmed to generate an alarm condition based on a
specific level of performance degradation. The Network screens present a
table that provides current error status and alarm threshold information.

Acceptable alarm thresholds are set for periods of 15 minutes (900 seconds)
and sampled every second. The error types listed in the following paragraphs
can be preset to a value between 0 and 900 seconds. Setting a field to “0”
(zero) disables the alarm on that statistic. To effectively disable alarm
reporting, set all fields to “0” (zero).