Reset timer, Reset alarms, Performance menu – Verilink WANsuite 5230 (34-00304.F) Product Manual User Manual

Page 204: Reset timer -8 reset alarms -8, Performance menu -8

Advertising
background image

5-8

W A N s u i t e 5 2 6 0 / 5 2 3 0

unit alarms a loss of DTR, which occurs when the Serial port detects that the
DTR signal is low.

Reset Timer

This field is the contiguous number of seconds that an alarm parameter must
be clear before the alarm is reset. Applicable values range from 000 through
899. A value of “000” means that the alarm never resets. Press

SELECT

to

change this threshold.

Reset Alarms

This option clears the alarm counts. To reset the alarms, press the

SCROLL

button to bring up the “Yes” option, and then press the

SELECT

button.

Performance Menu

The PERFORMANCE menu displays a history of the network error
parameters that are continuously monitored. This register lets you view the
24-hour performance totals from the unit. Although only the 5260’s
Performance menu is shown below in Figure 5.9, the parameters are the same
for the WANsuite 5260 Network 1 and Network 2 menus and also for the
Network menu in the WANsuite 5230.

Figure 5.9

WANsuite 5260 Performance Menu Tree

The parameters on this menu are the same as those on the Alarms Menu,
except for the three additional parameters defined below:

BES

Sets the Bursty Error Seconds (BES) threshold. A BES is a 1-second period
during which at least more than one but fewer than 320 CRC6 errors
occurred.

Net 1 24-hour

Perf

(read-only fields)

ES

SES

LOSS
OOFS
BPVS

CSS

RAS

AISS

UAS

CRCES

BES

LOFC

Net 1

Performance