F r o n t P a n e l L C D I n t e r f a c e

5-7

ES

Errored Seconds

the number of seconds for which at least one bit error has

occurred. A default threshold for alarm of 45 counts has been set for this
parameter.

SES

Severely Errored Seconds

the number of seconds for which bursts of errors

have occurred during the last 15 minutes. Often the noise on the E1 link is of
an impulsive random nature. The impulse noise tends to cause several bit
errors in sequence. The line then may become quiet and error-free for most of
the time. This parameter gives a measure of the impulsive error quality of the
line. The threshold for SES is set at 5.

LOSS

Loss Of Signal Seconds

the number of seconds for which the receiver failed

to see received signal strength above its lower operating limit. The default
alarm threshold for this condition is set at 5.

OOFS

Out Of Frame Seconds

the number of 1-second periods in which a frame

sync loss occurred. Often the receiver will be able to bridge bit errors and still
maintain frame synchronization. This is true since a frame consists of many
bits. The default alarm threshold for this condition is set at 5.

BPVS

Bipolar Violation Seconds

the number of times the signal failed to observe

the rules for changing the polarity of the logic “1” transmitted signal. The
default alarm threshold for this condition is set at 0, which means this alarm
is initially turned off.

CSS

Controlled Slip Seconds

indicates the number of seconds during which a

timing correction was needed due to buffer under-run or overflow. The default
alarm threshold for this condition is set at 5.

RAS

Remote Alarm Seconds

the number of seconds the RAI/yellow alarm has

been reported from the remote end of the E1 link. The default alarm threshold
for this condition is set at 0, which means this alarm is initially turned off.

AISS

Alarm Indication Signal Seconds

the number of seconds AIS has been

received. The default alarm threshold for this condition is set at 0, which
means this alarm is initially turned off.

UAS

Unavailable Seconds

the number of seconds for which data was not

available at the E1 port. The default alarm threshold for this condition is set at
0, which means this alarm is initially off.

NOTICE:

Alarm detection and generation are per the guidelines set forth in ITU-
T G.703 and G.704.

DTR Alarm

Read-only field that displays the current DTR Alarm status. This register
shows “OK” when no alarms are detected, and shows “ALRMED” when the

Advertising