W A N s u i t e 5 2 6 0 / 5 2 3 0

The Period Index field is used to define the period of time for which the
Traffic Meter statistics will be reported. It represents the 24-hour, 15-minute
buckets index. Selecting a period and then clicking the “Submit” button will
display the Traffic Meter Statistics for that period. Clicking on the “All Traffic
Meter Intervals” button at the bottom of the screen displays the Traffic Meter
Statistics for all intervals as defined below.

Summary

Represents the past 24 hours; reports the additive number of frames/octets, the
highest peak encountered for 24 hours, and the average for 24 hours.

Current

Reports on the current 15-minute interval.

Interval 1,

Interval 2,...,

Interval 96

Reports on intervals 1-96, which correspond to the periods completed 15
minutes ago, 30 minutes ago,..., 24 hours ago.

SNMP Details Screen

The unit detects and reports E1 network alarms and provides several options
for reporting them, one of which is SNMP traps. When a network alarm
occurs, the unit sends a trap message to as many as eight destinations on your
network. The unit will report each alarm by transmitting an SNMP “trap” to
each non-zero Trap IP address. The SNMP Details screen (Figure 3.38) lets
you configure the SNMP parameters described below.

Figure 3.38

SNMP Details Screen

Read Community

Accepts a character string identifying the group authorized to perform read
operations. The default setting is “Public.”

Write Community

Accepts a character string identifying the group authorized to perform write
operations. The default setting is “Private.”

Trap Community

Accepts a character string, which is included in SNMP traps generated by the
unit. The default setting is “Public.”