I n s t a l l a t i o n

2-3

5

By default, the “Baud Rate” field will display 115200 (bits per second). For
the purpose of this installation, do not change the displayed baud rate from
its default. Proceed directly to the next step.

6

Using the Tab key again, move the cursor to the “IP Address” field and
enter the appropriate IP address for the unit (xxx.xxx.xxx.xxx). If necessary,
repeat this process for the “Subnet Mask” and “Gateway Address” fields.

7

Next, move the cursor to the “Write To Unit” field and press the Enter key.
The program will prompt you to reset the unit.

8

To reset the unit, cycle the unit’s power (i.e., disconnect the power supply
cable from the unit and then reconnect it). The Configuration Wizard will
then automatically download the configuration information to the unit.

9

Note the status messages displayed at the bottom of the Configuration
Wizard screen. When the download is complete, your PC will beep and the
status message bar will display “Finished.”

10

Finally, move the cursor to the “Exit” prompt and press Enter. The
Configuration Wizard program will close.