3-43

BECN in CIR

Reports if Backward Explicit Congestion Notification (BECN) has been
received within CIR.

UAS Threshold

Sets the Unavailable Seconds (UAS) alarm threshold. This threshold is the
number of seconds after which the DLCI is unavailable. Setting this field to
“0” (zero) disables the alarm.

UAS Alarm

Reports if the UAS threshold has been exceeded.

The DLCI Details screen provides the user-activated buttons defined in the
table below.

DLCI Statistics Screen

Clicking the “DLCI Statistics” button on the DLCI Details screen will display
a summary (Figure 3.33) of the Transmit, Receive, and Performance statistics
for the selected DLCI for a specific period.

Figure 3.33

DLCI Statistics Screen

There are ninety-six 15-minute buckets available for DLCI statistics (sampled
every second). If the unit is powered on at 01:00 PM, the first interval will be

Button

Function

Submit

Sets and activates any DLCI parameters values that have been
changed.

Clear Alarms

Clears all DLCI alarms.

DLCI Statistics

Displays a table of the statistics for this DLCI.

DLCI Table

Displays a table of all DLCIs on a specific Frame Relay service,
with their state and alarm conditions.