Verilink WANsuite 5230 (34-00304.F) Product Manual User Manual

Page 56

Advertising
background image

3-26

W A N s u i t e 5 2 6 0 / 5 2 3 0

Round Trip Delay Size

Specifies the frame size (in bytes) of packets making the round-trip.

Round Trip Delay Rate

Specifies the rate (in seconds) at which Round Trip Delay packets are sent.

Status and Alarms Table

The table displayed at the bottom of the Frame Relay Service Details screen
reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field of the table and
clicking the “Submit” button. Table fields are describe below.

Active

Read-only field shows whether or not (No or Yes) an alarm is active.

LMI Type

Read-only status indicates ANSI, CCITT, LMI rev. 1, or Unknown.

FrameStart Status

Read-only status indicates Sourcing, Monitoring, or 0.

Rx Invalid Threshold

Number of invalid frames received during a 15-minute interval after which an
invalid alarm will be triggered. Default of “0” disables this alarm.

Rx Invalid Alarm

Status of this alarm indicates OK or Alarmed.

Tx Threshold

Number of bits per second sent during a 15-minute interval after which a Tx
alarm will be triggered. Default of 0 disables this alarm.

Tx Alarm

Status of this alarm indicates OK or Alarmed.

Rx Threshold

Number of bits per second sent during a 15-minute interval after which an Rx
alarm will be triggered. Default of 0 disables this alarm.

Rx Alarm

Status of this alarm indicates OK or Alarmed.

The Frame Relay Details screen provides the user-activated buttons described
in the following table:

NOTICE:

When a “Submit” command is executed, the frame relay link will be re-
initialized with the new parameters, causing a brief interruption in data
transfer.

Button

Function

Submit

Sets any values that have been changed.

Frame Relay Statistics

Opens the Frame Relay Statistics screen for the current
Frame Relay service.

DLCI Table

Opens the DLCI Table screen, which displays all the DLCIs
on the current service. Refer to DLCI Table Screen on
page 3-44 for
more information.

Clear Alarms

Clears all Frame Relay alarms.

Refresh

Refreshes data on the current page.