CHAPTER 12 PROGRAMMING CONTACT CLOSURES

Note

For information about how to configure the Click 112/114, see the Click Series User
Guide or the Click 112/114 Quick-Reference Guide.

Communication via SmartSensor Manager

To setup communication via SmartSensor Manager:
1 From the Channel-Alerts-Zone screen, click on Setup Output Communication.

2 Select Port 2 from the transmit output drop-down list. Port 2 is the data bus and is an

RS-485 port.

3 Select Z4 - Click 112/114 from the output format drop-down list to set up communica-

tion with a Click 112/114.

4 Click OK to save the communication changes.

5 Verify that detections are registering on the rack card and close SmartSensor Manager

if you are connected over the data bus.

Figure 12.1 – Setting Output Communications Using SmartSensor Manager

Click 172/174 Contact Closure Cards

The Click 172/174 cards are simple to program and require little on-site maintenance (see

Figure 12.2).

Note

The SmartSensor Advance Extended Range only works with the Click 112/114/104
card. It does not work with the Click 172/174/100 cards.