Speed (mph) and eta (s), Qualified count – Wavetronix SmartSensor Advance Extended Range (SS-200E) - User Guide User Manual

Page 87

Advertising
background image

86

CHAPTER 7 CHANNELS-ALERTS-ZONES

Figure 7.21 – Adjusting Zones for Advance (left) and Advance Extended Range (right)

Speed (mph) and ETA (s)

In addition to range, zone detections can also be filtered by speed and by the estimated time

of arrival to the stop bar. Click anywhere in the Speed or ETA area and the Edit Basic Filters

screen will appear (see Figure 7.22).

Figure 7.22 – Edit Basic Filters Screen

Edit the min and max values in the speed filter to set the range of qualified speeds. The min-

imum speed value is 1 mph (2 kph) and the maximum speed value is 100 mph (161 kph).

On the previous window, check the box to the left of the Speed label to enable the speed

filter (only speeds within the range will activate zone outputs); uncheck the box to disable

the speed filter (all speeds will activate zone outputs).

Edit the min and max values in the ETA filter to set the range of qualified ETAs. The mini-

mum ETA value is 0.1 seconds and the maximum ETA value is 25.4 seconds. If you try

to raise the max ETA value above 25.4, the filter will be set to INF, which will accept any

vehicle with an estimated time of arrival greater than the minimum.

On the previous window, check the box to the left of the ETA label to enable the ETA filter

(only ETAs within the range will activate zone outputs); uncheck the box to disable the ETA

filter (all ETAs will activate zone outputs).

Qualified Count

A qualified detection is a detection in a zone that meets the specified range, speed and ETA

filters. The SmartSensor Advance provides two very powerful detection qualification filters:

Advertising