CHAPTER 7 • CHANNELS-ALERTS-ZONES

81

Normal channels consist of four alerts, each containing four zones. A normal channel’s

output is a logical combination of the channel’s alert, zone, delay and extend settings (see

Delay and Extend sections under Latched Channels). The normal channel’s output becomes

active when the associated alert and zone logic, the channel delay or the channel extend are

satisfied.

Each enabled normal channel must have at least one enabled alert. If you attempt to save an

invalid channel configuration, the following message is displayed (see Figure 7.13).

Figure 7.13 – Invalid Channel Configuration

Latched Channel

Latched channels consist of two alerts (ON and OFF), each containing up to four zones (see

Figure 7.14). A latched channel, by definition, has exactly two enabled alerts that cannot be

disabled.

Channel 1

ON

Alert

OFF

Alert

Zone

1

Zone

2

Zone

3

Zone

4

Zone

1

Zone

2

Zone

3

Zone

4

Figure 7.14 – Latched Channel Hierarchy

Latched channels differ from normal channels in that the channel output remains in a given

state until a contradictory alert is exclusively activated, or a maximum latch time has ex-

pired (see Figure 7.15).