CHAPTER 2 • CONNECTING POWER AND SURGE PROTECTION

33

˽

DC Surge OK – Indicates that DC surge protection is operational.

˽

TD – Indicates when data is transmitted over the T-bus or over the control bridge. This

LED does not indicate data transmitted on the A or B ports.

˽

RD – Indicates when data is received over the T-bus or over the control bridge. This

LED does not indicate data received on the A or B ports.

Note

If the DC Surge OK LED is not on when the Click 222 is powered, call Wavetronix Tech-
nical Services for assistance.

The Click 222 provides the following three independent serial connections:

˽

Top jack – control bridge

˽

Middle jack – dedicated communications for sensor 2 detection calls

˽

Bottom jack – dedicated communications for sensor 1 detection calls

The control bridge enables a multi-drop shared communication bus between all sensors

connected to the backplate. This allows control of all Advance sensors, rack cards and other

connected Click devices. The remaining two serial connection ports provide communica-

tions to only one sensor each, as outlined above.

On a four-sensor preassembled backplate (see Figure 2.7):

˽

The sensor wired into the leftmost terminal blocks will be connected to ports A and C

on the Click 222 on the left. Port A is for detection calls and port C is connected to the

control bridge.

˽

The sensor wired to the second set of terminal blocks will be wired to ports B and D

on the Click 222 on the left. Port B is for detection calls and port D is connected to the

control bridge.

˽

The sensor wired to the third set of terminal block from the left will be wired to ports

A and C on the Click 222 on the right.

˽

The sensor wired to the rightmost terminal block will be wired to ports B and D on the

Click 222 on the right.