Wavetronix SmartSensor Advance Extended Range (SS-200E) - User Guide User Manual

Page 81

Advertising
background image

80

CHAPTER 7 CHANNELS-ALERTS-ZONES

Channel 1

Alert 1

Zone

1

Alert 2

Alert 3

Alert 4

Zone

2

Zone

3

Zone

4

Zone

4

Zone

3

Zone

2

Zone

1

Zone

1

Zone

2

Zone

3

Zone

4

Zone

1

Zone

2

Zone

3

Zone

4

Figure 7.11 – Normal Channel Hierarchy

The CAZ Setup screen below shows a tabbed view of each detection channel and its as-

sociated alerts and zones (see Figure 7.12). The eight tabs at the top of the screen represent

the sensor’s eight channels, with the selected tab showing the channel number and channel

name; the middle portion of the screen contains alert configuration parameters; and the

lower portion of the screen contains zone configuration parameters.

Channels

Alerts

Zones

Figure 7.12 – Setup Channels-Alerts-Zones Screen

The OK, Undo and Cancel buttons pertain to ALL changes made in the CAZ Setup job and

not to individual channels, alerts or zones. The OK button saves the settings to the sensor;

the Undo button restores the settings to the screen’s initial values; and the Cancel button

closes the screen without saving any changes.

Advertising