APPENDIX

Maximum Cable Length for SS200V Communications

To achieve reliable wired communications, the selected baud rate must be compatible with

the length of the cable run. The table below shows the cable length recommendations for

wired communications (see Table B.2):

Baud Rate

RS-485

115.2

300 ft. (91.4 m)

57.6

600 ft. (182.9 m)

38.4

800 ft. (243.8)

19.2

1000 ft. (304.8 m)

9.6

2000 ft. (609.6 m)

Table B.2 – Maximum Cable Length for Wired Communications

Given the power and communication requirements listed above, here is a summary of some

power and communication cable guidelines (see Table B.3):

Length

Cable

Comm. Channel 1 Comm. Channel 2

0–1500 ft. (0–457.2
m)

6-conductor Cable

Native RS-485

Native RS-485

1500–2000 ft.
(457.2–609.6 m)

6-conductor Cable

Native RS-485

NA

2000–2500 ft.
(609.6–762 m)

Alternate cable for power
and communications

Native RS-485

Native RS-485

Table B.3 – Summary of SS200V standard cable length options

Maximum Cable Length for Powering SS200

The table below shows the cable lengths for power when using a SmartSensor Advance

model SS200 (see Table B.4):

Cable Gauge

24 Volts

12 Volts

20 AWG (9-conductor)

600 ft. (182.88 m)

110 ft. (33.52 m)

Add RTS/CTS (9-conductor)

1000 ft. (304.8 m)

185 ft. (56.38 m)

Add TD/RD (9-conductor)

1400 ft. (426.72 m)

260 ft. (79.24 m)

14 AWG

2500 ft. (762 m)

450 ft. (137.16 m)

12 AWG

3900 ft. (1.18 km)

700 ft. (213.36 m)

10 AWG

6000 ft. (1.82 km)

1050 ft. (320.04 m)

8 AWG

9900 (3.01 km)

1750 ft. (533.4 m)

6 AWG

14000 (4.26 km)

2500 ft. (762 m)

Table B.4 – Maximum Cable Length for Power (model SS200)