CHAPTER 6 SENSOR CONFIGURATION

Figure 6.6 – Reboot

If you were in the process of manually editing detection thresholds, it will ask you if you

would like to save these changes to the sensor’s flash before rebooting (see Figure 6.7). If you

do not save these changes they will be discarded.

Figure 6.7 – Save Changes

During the reboot time, the power button will turn red (see Figure 6.8), but once the sensor

has rebooted it will go back to green again.

Figure 6.8 – Red Button During Reboot

Editing Sensitivity

If missed detections are consistently noticed, the sensor’s sensitivity can be adjusted. De-

creasing the detection threshold levels in areas where trackers begin to disappear will reduce

the number of missed detections. To increase the sensor’s sensitivity, decrease the detection

threshold levels; to decrease the sensor’s sensitivity, increase the detection threshold levels.