Riverstone Networks RS Switch Router User Guide Release 8.0 4-5

Hot Swapping Line Cards and Control Modules

Hot Swapping a Switching Fabric Module (RS 8600 only)

After you enter this command, the Offline LED on the Control Module lights, and messages appear on the console
indicating the Control Module is inoperative.

4.4.2

Removing the Control Module

To remove a Control Module from the RS:

1.

Make sure that none of the LEDs on the Control Module are lit.

2.

Loosen the captive screws on each side of the Control Module.

3.

Carefully remove the Control Module from its slot in the RS chassis.

4.4.3

Installing a Control Module

To install a new Control Module or line card into the slot:

Note

You can install either a line card or a Control Module in slot CM/1, but you can
install only a Control Module in slot CM.

1.

Slide the Control Module or line card all the way into the slot, firmly but gently pressing it in place
to ensure that the pins on the back of the card are completely seated in the backplane.

Note

Make sure the circuit card (and not the metal plate) is between the card guides.
Check both the upper and lower tracks.

2.

Tighten the captive screws on each side of the Control Module or line card to secure it to the chassis.

-

On a line card, the Online LED lights, indicating it is now active.

-

On a secondary Control Module, the Offline LED lights, indicating it is standing by to take over
as the primary Control Module if necessary.

4.5

HOT SWAPPING A SWITCHING FABRIC MODULE
(RS 8600 ONLY)

The RS 8600 has slots for two Switching Fabric Modules. While the RS 8600 is operating, you can install a second
Switching Fabric Module. If two Switching Fabric Modules are installed, you can hot swap one of them.

When you remove one of the Switching Fabric Modules, the other goes online and stays online until it is removed or
the RS 8600 is powered off. When the RS 8600 is powered on again, the Switching Fabric Module in slot “Fabric 1,”
if one is installed there, becomes the active Switching Fabric Module.