ATL Telecom R1-SW Ethernet Switch User Manual
Page 163
Configuring SNMP and RMON
8-29
(Continued)
Command
Task
y
absolute: Option for testing each MIB variable directly.
y
delta: Option for testing the change between MIB variables
y
rising: Option for triggering alarm when the monitored value
exceeds the rising threshold
y
falling: Option for triggering alarm when the monitored value
exceeds the falling threshold
y
both: Option for triggering alarm when the monitored value
exceeds the rising or falling threshol
y
<rising-threshold>: Value at which the alarm is triggered
(0 ~ 2147483647)
y
<falling-threshold>: Value at which the alarm is reset (0
~ 2147483647)
y
<rising-event-index>: Event number to trigger when the
rising threshold exceeds its limit. (0 ~ 65535)
y
<falling-event-index>: Event number to trigger when
the falling threshold exceeds its limit. (0 ~ 65535)
y
owner <alarm-owner> : option for specifying an owner for the
alarm.
end
2.
Return to Privileged mode.
show rmon
3.
Verify the configuration.
The following example shows how to configure RMON alarm group and check the result:
# configure terminal
(config)# rmon alarm 1 10 pkts 1 absolute both threshold 1000 100 event-index 1
1 owner aaa
(config)# end
# show rmon
RMON:
Enabled
Extended RMON:
Extended RMON module is not present
[statistics]
index status dataSource
----- -------------- -----------------------------
1
valid
ifIndex.1 (Gi 1/1)
[history]
index status dataSource
----- --------------
-----------------------------
1 valid
ifIndex.1 (Gi 1/1)