Outputs – West Control Solutions KS98-1 User Manual

Page 14

Advertising
background image

Signal input INP5

Differential amplifier input

Up to 6 controllers can be cascaded, if there is no other galvanic
connection between them. If there is, only 2 inputs can be cascaded.

Direct current and voltage

Technical data as for INP1, except for:

Limiting frequency: = 0.25 Hz, Measurement cycle: 800 ms

Input resistance (voltage):

³ 500 kW

Signal input INP6

Limiting frequency: = 0.5 Hz, Measurement cycle: 400 ms

Potentiometric transducer

Technical data as for INP1, except for:

R

total

inkl. 2 x RL

Error

Resolution

0...1000

W

£ 0.1 %

£ 0.04 W

Direct current 0/4...20 mA

Technical data as for INP1

Signal inputs INP3, INP4 (option C)

Galvanically-isolated differential amplifier inputs.
Limiting frequency: fg = 1 Hz, Measurement cycle: 100 ms

Direct current

Technical data as for INP1, except Ri = 43

W

Control inputs di1...di12

di1, di2: standard

di3...d7: Option B

di8...di12: Option C

Opto-coupler

Nominal voltage: 24 VDC, external

Current sink (IEC 1131 Type 1)

Logic „0“ (Low): –3...5 V, Logic „1“ (High): 15...30 V

Current demand: approx. 6 mA (for galvanic connections and isola-
tion see page 25).

Built-in transmitter supply (optional)

Can be used to energize a two-wire transmitter or up to 4
opto-coupler inputs.Galvanically isolated.

Output:

³ 17.5 VDC, max. 22 mA

Short-circuit proof.

Factory setting
The transmitter supply is available at terminals A12 and A14

+

See page 25, Configuration see page 21

Outputs

Relay outputs (OUT4, OUT5)

Relays have potential-free change-over contacts.

Max. contact rating:

500 VA, 250 V, 2 A with 48...62 Hz, cos

j ³ 0,9

Minimum rating: 12 V, 10 mA AC/DC

Number of switching cycles electrical: for I = 1A/2A

³ 800,000 /

500,000 (at ~ 250V / (resistive load))

!

When connecting a contactor to a relay output, RC
protective circuitry to specification of the contactor
manufacturer is required. Varistor protection is not
recommended!

Outputs OUT1, OUT2

Relay or current/logic signal, depending on version:

OUT1, OUT2 as current outputs

Galvanically isolated from the inputs

0/4...20 mA, selectable

Signal range: 0...22 mA

Resolution:

£ 6 mA (12 bits)

Error:

£ 0.5%

Load:

£ 600 W

Load effect:

< 0.1%

Limiting frequency: approx. 1 Hz Output cycle: 100ms

OUT1, OUT2 as logic signal

0 /

³ 20 mA with a load ³ 600 W

0 / > 12 V with a load

³ 600 W

Output OUT3 (Option C)

Technical data as for OUT1, OUT2, as current output

Control outputs do1..do6

Galvanic isolated Opto-coupler outputs, galvanic isolation see
page 25 and text.

Grounded load: common positive control voltage

Switch rating: 18...32 VDC; Imax

£ 70 mA

Internal voltage drop:

£ 0.7V with I

max

Protective circuit: thermal, switches off with overload.

Supply 24 V DC external

Residual ripple

£ 5%

ss

Technical data

9499-040-82711

I-14