West Control Solutions KS98-1 User Manual

Page 182

Advertising
background image

Digital outputs:

et-err

0 = no engineering error

1 = engineering error (several module blocks at a slot output).

slots not connected.

slotId

0 = correct slot allocation
1 = faulty slot allocation (module type). Faulty coupler module

valid

0 = no data
1 = data could not be received
fail 1 faulty connection or measurement error on channel 1
fail 2 faulty connection or measurement error on channel 2
ready ready message after command handling

Analog inputs:

connection of one of the slot outputs of the RM201-1-node block

Analog outputs:

AI 1

1st measured value of strain gauge channel 1

AI 2

2nd measured value of strain gauge channel 2

Parameters:
MTyp 1/2

module type 0: RM225 = strain gauge

STyp 1/2

0: -4 +4mV/V

Unit 1/2

mV/V

Tf 1/2

filter time constant input 1 ... 2 in (s) 0 ... 999 999 (0,5

)

x0 1/2

scaling start value input 1 ... 2 -29 999 ... 999 999 (0)

x100 1/2

scaling end value input 1 ... 2 -29 999 ... 999 999

(100)

Fail 1/2

signal action in case of sensor error
0:upscale
1:downscale

X1in 1/2

measured value correction input value
segment point 1 > input 1...2 -29 999 ... 999 999

(0)

X1out 1/2 measured value correction output value

segment point 1 > input 1...2 -29 999 ... 999 999

(0)

X2in 1/2

measured value correction input value
segment point 2 > input 1...2 -29 999 ... 999 999

(100)

X2out 1/2 measured value correction output value

segment point 2 > input 1...2 -29 999 ... 999 999 (100)

I/O extensions with CANopen

9499-040-82711

III-182

RM_DMS (strain gauge module (No. 22))

Advertising