Frame 12 Mechanical Installation

Chapter 8

Disconnect the Small Capacitors from the Input Terminals

Follow the steps below to disconnect the small capacitors from the input
terminals.

IMPORTANT

It is not necessary to remove the power wiring from the terminals in order to
insulate the capacitor leads.

Task

Description
Remove the screws and lock washers that secure each of the three capacitor supply wires to the input power
terminals.
Insulate the capacitor leads and leave disconnected.

Install and tighten the screws and lock washers only.

IMPORTANT

Do not re-install the capacitor leads.

A

B

C

L1

L2

L3

Capacitor

Insulator

Capacitor lead - leave
disconnected

Input power terminal

A

B

C

Front View of Input
Power Terminals

Side View of Input
Power Terminals

Advertising