Auxiliary power supply, I/o wiring examples, Auxiliary power supply i/o wiring examples – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual

Page 37

Advertising
background image

Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013

37

Control Wiring for PowerFlex 700H Drives

Chapter 2

Auxiliary Power Supply

You may use an auxiliary power supply to keep the 700H control unit energized,
when input power is de-energized. This provides back-up power for the control
unit and is sufficient for setting parameters. Connect 24V DC power to pin 19
and 24V DC common to pin 20 of the 24V DC version of the I/O card.

Table 13 - Auxiliary Power Supply Specifications

If 24V terminals of several drives are connected in parallel, it is recommend that a
diode circuit to block current flow in the opposite direction is used. Reverse
current flow could damage the control board.

I/O Wiring Examples

Voltage

Current (Min)

Current (Max)

24V DC ± 15%

150 mA

250 mA

Input/Output

Connection Example

Required Parameter Changes

Potentiometer Unipolar
Speed Reference
10k

Ω

Pot. Recommended

(2 k

Ω

Minimum)

Set I/O configuration (see Analog I/O

Configuration on page

36

).

Adjust Scaling:

Parameters 91 [Speed Ref A Hi] / 92
[Speed Ref A Lo] and 325 [Analog In 2 Hi] /
326 [Analog In 2 Lo]

View Results:

Parameter 002 [Commanded Speed]

Joystick Bipolar Speed
Reference

±

10V Input

Important: See the Attention
statement on page

31

for

important information on
bipolar wiring.

Set I/O configuration (see Analog I/O

Configuration on page

36

).

Set parameter 190 [Direction Mode] = 1

“Bipolar”

Adjust Scaling:

Parameters 91 [Speed Ref A Hi] / 92
[Speed Ref A Lo] and 325 [Analog In 2 Hi] /
326 [Analog In 2 Lo]

View Results:

Parameter 002 [Commanded Speed]

:19

:20

From Auxiliary

Power Supply

:19

:20

:19

:20

:19

:20

24V dc

Power

24V dc

Common

3

4

6

6

7

3

6

4

7

5

Advertising