Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual

Page 51

Advertising
background image

Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013

51

Control Wiring for PowerFlex 700S Drives with Phase II Control

Chapter 3

Primary Encoder Interface -
Internal Supply
Supports 5V/12V DC
differential encoders with
internal power supply.

Used as primary closed loop
speed feedback.

Using Encoder 0 as speed feedback:
Par 222 [Motor Fdkbk Sel] = 0 - “Encoder 0” (default)
Par 232 [Encoder0 PPR] = Pulses/Rev for installed encoder

Primary Encoder Interface -
External Supply

Used as primary closed loop
speed feedback.

Using Encoder 0 as speed feedback:
Par 222 [Motor Fdkbk Sel] = 0 - “Encoder 0” (default)
Par 232 [Encoder0 PPR] = Pulses/Rev for installed encoder

Input/Output

Connection Example

Required Parameter Changes

A-

A

Encoder

13

14

15

16

17

18

19

20

21

22

23

24

B-

B

Z-

Z

-

+

Power +V

Common -V

Shield

A-

A

Encoder

13

14

15

16

17

18

19

20

21

22

23

24

B-

B

Z-

Z

-

+

Advertising
This manual is related to the following products: