180

Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013

Appendix A

Specifications

Table 13 - 540 Volt DC Input Frames 9…14 Drive Protection Devices

20xF1K0

13

1000

1038

1300 (1 per phs)
650 (2 per phs)

2300

1300 (1 per phs)
650 (2 per phs)

3000

170M6466

(5)

3000

1300

900

927

1200 (1 per phs)
600 (2 per phs)

2000

1200 (1 per phs)
600 (2 per phs)

2700

170M6466

(5)

2700

1200

20xF1K1

13

1100

1189

1500 (1 per phs)
750 (2 per phs)

2600

1500 (1 per phs)
750 (2 per phs)

3500

170M6466

(5)

3500

1500

1000

1038

1300 (1 per phs)
650 (2 per phs)

2300

1300 (1 per phs)
650 (2 per phs)

3000

170M6466

(5)

3000

1300

20xF1K5

14

1500

1511

1900 (1 per phs)
650 (3 per phs)

3300

1900 (1 per phs)
650 (3 per phs)

4500

170M6466

4500

1900

1300

1310

1700 (1 per phs)
575 (3 per phs)

2900

1700 (1 per phs)
575 (3 per phs)

3900

170M6466

3900

1700

20xF1K9

(2)

14

1800

1914

2400 (1 per phs)
800 (3 per phs)

4200

2400 (1 per phs)
800 (3 per phs)

5700

170M6466

5700

2400

1500

1511

1900 (1 per phs)
650 (3 per phs)

3200

1900 (1 per phs)
650 (3 per phs)

4500

170M6466

4500

1900

20xF2K2

(2)

14

2000

2267

2900 (1 per phs)
950 (3 per phs)

5000

2900 (1 per phs)
950 (3 per phs)

6700

170M6466

6700

2900

1800

1914

2400 (1 per phs)
800 (3 per phs)

4200

2400 (1 per phs)
800 (3 per phs)

5700

170M6466

5700

2400

(1) 20DF820 drives (ND) are only capable of producing 95% of starting torque under 10 Hz.
(2) Not available with 700S Control.
(3) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
(4) Maximum protection device size is the highest rated device that supplies drive protection.
(5) These fuses and disconnect are supplied with AC input NEMA/UL Type 1 drives.
(6) Inverse time breaker. Ratings shown are maximum.
(7) Maximum allowable rating by US NEC. Exact size must be chosen for each installation.
(8) Motor Circuit Protector - instantaneous trip circuit breaker. For US NEC minimum size is 125% of motor/drive FLA. Ratings shown are suggested. Instantaneous trip settings must be set to US NEC code. Not

to exceed 1300% FLA.

Drive Catalog
Number

Fram

e

kW Rating

Input
Ratings

Dual Element Time Delay Fuse

Non-Time Delay Fuse

Bussmann Style Semi-
Conductor Fuse

Circuit
Breaker

(6)

Motor Circuit
Protector

(8)

ND

HD

Amps

Min.

(3)

Max.

(4)

Min.

(3)

Max.

(4)

Max.

(7)

Max.

Drive Catalog Number Frame kW Rating

DC Input Ratings Fuse

Bussmann Style Fuse

ND

HD

Amps

20xH261

9

132

-

307

500

170M6608

-

110

241

500

170M6608

20xH300

9

160

-

353

630

170M6610

-

132

288

630

170M6610

20xH385

10

200

-

453

700

170M6611

-

160

353

700

170M6611

20xH460

10

250

-

541

900

170M6613

-

200

453

900

170M6613

20xH500

10

250

-

589

500 (2 per phs)

170M6608

-

250

494

500 (2 per phs)

170M6608

20xH590

11

315

-

695

550 (2 per phs)

170M6609

-

250

612

550 (2 per phs)

170M6609

20xH650

11

355

-

765

630 (2 per phs)

170M6610

-

315

695

630 (2 per phs)

170M6610

20xH730

11

400

-

859

700 (2 per phs)

170M6611

-

355

765

700 (2 per phs)

170M6611

20xH820

12

450

-

965

700 (2 per phs)

170M6611

-

400

859

700 (2 per phs)

170M6611

20xH920

12

500

-

1083

550 (3 per phs)

170M6609

-

450

965

550 (3 per phs)

170M6609

20xH1K0

12

560

-

1213

630 (3 per phs)

170M6610

-

500

1083

630 (3 per phs)

170M6610

20xH1K1

13

630

-

1354

2400

170M7107

-

560

1213

2400

170M7107

20xH1K3

13

710

-

1530

2400

170M7107

-

630

1354

2400

170M7107