Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual

Page 49

Advertising
background image

Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013

49

Control Wiring for PowerFlex 700S Drives with Phase II Control

Chapter 3

Table 17 - TB1 Terminal Descriptions

Table 18 - TB2 Terminal Descriptions

Terminal

Signal

Factory
Default

Description

Related
Parameter

1

Analog Input 1 Comm.

(Volt)

Bipolar, differential input, +/-10V, 0-20 mA, 13 bit + sign
20 k

Ω

impedance at Volt; 500

Ω

impedance at mA

(1)

800

2

Analog Input 1 (+/-)

3

Shield

NA

Analog Input shield

4

Analog Input 2 Comm.

(Volt)

Bipolar, differential input, +/-10V, 0-20 mA, 13 bit + sign
20 k

Ω

impedance at Volt; 500

Ω

impedance at mA

806

5

Analog Input 2 (+/-)

6

Analog Input 3 [NTC-] Comm.

(Volt)

Differential input, 0-10V, 10 bit (for motor control mode FVC2, this is the temperature
adaptation input).

812

7

Analog Input 3 [NTC+]

8

Shield

NA

Analog Output shield

9

Analog Output 1 (-)

(Volt)

Bipolar, differential output, +/-10V, 0-20 mA, 11 bit + sign
2 k

Ω

minimum load

832, 833

10

Analog Output 1 (+)

11

Analog Output 2 (-)

(Volt)

839, 840

12

Analog Output 2 (+)

13

+10V Reference

NA

Rating: 20 mA maximum load (Recommend 5 k

Ω

pot)

14

Reference Common

NA

15

-10V Reference

NA

16

Encoder A

NA

Normal current draw per channel: 20 mA

230…233

17

Encoder A (Not)

NA

18

Encoder B

NA

19

Encoder B (Not)

NA

20

Encoder Z

NA

21

Encoder Z (Not)

NA

22

Encoder Reference (+)

NA

12 or 5V DC power supply for primary encoder interface
Rating: 300 mA maximum

23

Encoder Reference (-)

NA

24

Encoder Shield

NA

Connection point for encoder shield

(1) The analog inputs are not isolated. However, the analog inputs can be connected in series when using current mode. Note that at 20 mA the voltage source must be capable of providing 10V DC at the drive

terminals for one drive - - 20V DC is required for two drives and 30V DC is required for three drives.

1

2

3

4

5

6

7

8

9

12

10

11

13

14

15

16

17

18

19

20

21

22

23

24

Terminal

Signal

Factory
Default

Description

Related
Parameter

1

24V DC Common (-)

NA

Drive supplied 24V DC logic input power
Rating: 300 mA maximum load

2

24V DC Source (+)

NA

3

Digital Output 1

24V DC Open Collector (sinking logic)
Rating: Internal Source = 150 mA max.
External Source = 750 mA

816, 847

4

Digital Output 1/2 Com

NA

Common for Digital Output 1 & 2

5

Digital Output 2

24V DC Open Collector (sinking logic)
Rating: Internal Source = 150 mA max.
External Source = 750 mA

851, 852

6

Relay Output 3 (NC)

Relay contact output
Rating: 115V AC or 24V DC = 2 A max.
Inductive/Resistive

856, 857

7

Relay Output 3 Com

NA

8

Relay Output 3 (NO)

9

Digital Input 1-3 Com

NA

Common for Digital Inputs 1-3

10

Digital Input 1

High speed 12V or 24V DC

(1)

, sinking

Load:15 mA at 24V DC

825

11

Digital Input 2

826

12

Digital Input 3

Load:15 mA at 24V DC sourcing

827

13

Digital Input 4-6 Com

NA

Common for Digital Inputs 4-6

14

Digital Input 4

Load: 10 mA at 24V DC sinking/sourcing
Load: 7.5 mA at 115V AC
Note: The 115 VAC Digital Inputs can withstand 2 mA of leakage current without turning on. If an
output device has a leakage current greater than 2 mA, a burden resistor is required. A 68.1 K

Ω

resistor with a 0.5 W rating should be used to keep the 115 VAC output below 2 mA.

828

15

Digital Input 5

829

16

Digital Input 6

HW Enable

830

(1) Digital Inputs 1 and 2 are configured for 12V or 24V DC via DIP switches S3-1 and S3-2, respectively. 24V DC is the default setting.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Advertising