Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual

Page 96

Advertising
background image

96

Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013

Chapter 7

Frame 11 Mechanical Installation

Insulate Terminal X4 on the Rectifier Circuit Board

Follow the steps below to insulate terminal X4 on the rectifier circuit board (see

Figure 32

on page

94

for rectifier board location).

Task

Description
Remove the screw from the X4 connection on the rectifier circuit board.

Insulate the top and bottom of the X4 connection on the rectifier circuit board.

IMPORTANT

Do not install the screw and washer that was removed from this connection.

A

B

X1

X4

X41

X1

X4

X41

A

B

Rectifier Circuit Board

Side View of Power Structure

Advertising
This manual is related to the following products: