Finecut (mild steel), Finecut (mild steel) -34, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 106

Advertising
background image

Machine Torch SeTup

6-34

powermax

105

Service Manual

FineCut (Mild Steel)

Air flow rate – slpm/scfh

Hot

181 / 384

Cold

191 / 404

Metric

Material

thickness

Current

torch-

to-Work

Distance

Initial Pierce Height

Pierce Delay

time

Recommended

Cut Speed

Voltage

mm

A

mm

mm

%

seconds

(mm/min)

Volts

0.5

40

1.5

2.25

150

0.0

8250

78

0.6

8250

78

0.8

0.1

8250

78

1

45

0.2

8250

78

1.5

0.4

6400

78

2

4800

78

3

0.5

2750

78

4

0.6

1900

78

English

Material

thickness

Current

torch-

to-Work

Distance

Initial Pierce Height

Pierce Delay

time

Recommended

Cut Speed

Voltage

A

inches

inches

%

seconds

ipm

Volts

26GA

40

0.06

0.09

150

0.0

325

78

24GA

325

78

22GA

0.1

325

78

20GA

325

78

18GA

45

0.2

325

78

16GA

0.4

250

78

14GA

200

78

12GA

0.5

120

78

10GA

95

78

Advertising