Test 1 – voltage input, Test 1 – voltage input -43, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 181

Advertising
background image

TROUBLESHOOTING AND SYSTEM TESTS

powermax

105 Service Manual

8-43

Test 1 – Voltage input

Symptom: Voltage fault (0-60-0, -1 or -2)

• Check the line voltage at the top of the power switch (S1) with the switch in the OFF position.
• Check the input voltage to the input diode bridge with the switch in the ON position.

- The AC voltage between any 2 input wires should equal the line voltage.

• If there is proper voltage to the power switch and low voltage to the input diode bridge, replace the power

switch.

• Check the output voltage of the input diode bridge.

- Output VDC = Line Voltage x 1.414 VDC.

Note: All values are ±15%.

Three phase

L1

Black (CSA)

Brown (CE)

L2

White (CSA)

Black (CE)

L3

Red (CSA)

Gray (CE)

PE

Green (CSA)

Green/Yellow (CE)

• If there is a fault and the diode bridge output value is correct:

- Display the service screen and confirm that the value “VL” is ±15% of AC line voltage.

• If there is a fault and the “VL” value is correct:

- Verify the DSP board by replacing it with a known good board.
- If DSP board is not the problem, replace the power board and the PFC IGBT module (CSA and 230-400 V

CE units only).

LV

3 inputs to GRD

LV/1.732

Ground (GRD)

Black wire

LV

LV

LV X

1.414

LV = incoming line voltage