Replace the rear end panel, Powermax – Hypertherm Powermax105 Service Manual User Manual

Page 282

Advertising
background image

Power SuPPly ComPonent rePlaCement

9-84

powermax

105 Service Manual

Replace the rear end panel

1. Remove the screw securing the ground wire(s) to the air filter housing.

Note: There will be two ground wires if the optional CNC

interface connector is installed in the rear panel.

2. Unplug the two wire connectors from the terminals on top of the

pressure switch.

3. If the optional CNC interface is installed, remove the two mounting

screws securing it to the rear end panel.

4. Grasp the filter bowl with your right hand.
5. Push down the thumb latch and rotate the filter bowl approximately 45

degrees to the right.

6. Pull the filter bowl straight down to remove. You can see the white

filter element and retaining nut.

7. Remove the filter element by unscrewing (counterclockwise) the

plastic retaining nut.

8. Remove the gas fitting from the rear panel.

Optional RS485

connector

Optional CNC

interface connector

Pressure

switch

Ground wire

screw

Air filter

subassembly

9. Remove the three air filter subassembly mounting screws.
10. Lift the air filter subassembly out of the power supply.
11. If the optional RS485 connector is installed, remove it by unplugging the five wires from the connector terminals

inside the power supply and removing the two mounting screws from the rear end panel.

Filter bowl

Gas fitting

Air filter

subassembly

mounting screws (3)

Thumb latch

Remove

Optional RS485

connector

Advertising