TroubleshooTing and sysTem TesTs

powermax

105 Service Manual

8-37

Problem

Meaning

Causes

Solution

The power ON LED is

illuminated and no fault

codes are displayed, but

no gas flows when the

torch trigger is pulled.

The start signal is

not reaching the

control board.

• The torch or

torch lead may

be damaged.

• The power board

may be faulty.

• The control

board may be

faulty.

• Inspect the torch and torch lead for

damage.

• Verify that the start icon appears on the

LCD screen when the trigger is pulled. If

it does not, perform Test 7 to check the

start signal from the power board.

Power ON LED blinks or

goes out while cutting.

A power component

is shorted.

• Faulty fan.

• Perform Test 11.

• Faulty power

board or IGBT.

• Perform Tests 1, 2, or 3.

• Faulty DSP

board.

The arc does not transfer

to the workpiece.

• Clean the area where the work clamp

contacts the workpiece to ensure a

good metal-to-metal connection.

• Inspect the work clamp for damage and

repair as necessary.

• The pierce height distance may be

too large. Move the torch closer to the

workpiece and fire the torch again.

Gas flows from the

torch at power-up when

neither the torch trigger

nor a remote start is

activated.

The electronic

regulator, power

board, or control

board is faulty.

• Faulty electronic

regulator.

• Faulty power

board.

• Faulty DSP

board.

• Perform Test 9.

The incoming gas

pressure is too high.

• The gas pressure

from the

compressor or

cylinder may be

too high.

• Check the gas supply to make sure that

it does not exceed 9.3 bar (135 psi). If

necessary, reduce the pressure.